Page 146 - Eagle Scientific Ltd - Catalogue
P. 146
ES
Dissolved Oxygen
DISSOLVED OXYGEN METERS
DISSOLVED OXYGEN METER, HAND HELD, EXTECH
9-in-1 meter which measures Dissolved Oxygen Concentration/Saturation, pH, mV,
Conductivity, TDS, Salinity, Resistivity and Temperature. Features automatic
salinity compensation and manual barometric pressure compensation for D.O.
measurements, waterproof housing (meets IP57), one button pH calibration (4, 7
and 10pH), choice of 3 point pH calibration for better accuracy, one point
conductivity calibration, automatic temperature compensation (non-linear
compensation for purified water <10μS/cm to improve measuring accuracy),
memory stores up to 400 readings, large blue backlit dual LCD display and auto
power off.
Technical Data
Ranges:
D.O: 0.0-40.0mg/l, 0.0-200.0% saturation
Temperature: 0.0-100.0ºC
pH: 2.0-19.
mV: -1999 - +1999mV
Conductivity: 0.0-199.9mS
T.D.S.: 0.0-100.0g/l
Salinity: 0.0-100.0ppt C37-2100
Resistivity: 0.0-100.0MΩ/cm
Resolution:
D.O.: 0.01mg/l, 0.1% saturation
Temperature: 0.1ºC
pH: 0.01
mV: 1.0mV
Conductivity: 0.01μS
Accuracy:
D.O: ±1.5%mg/l of full scale, ±1.5% of full scale saturation
pH: ±0.02
mV: ±0.15
Power Supply: 2 x AA Batteries
Supplied complete with D.O. probe with 3 membrane caps and 30ml internal fill
solution, pH/mV/Temperature Electrode, polymer conductivity cell, pH calibration
solutions (4, 7 and 10pH), conductivity calibration solutions (1413μS), 2 x AA
batteries and a hard carry case.
C37-2100 Dissolved Oxygen Meter
Spare Parts and Accessories
C37-2101 Dissolved Oxygen Probe, spare
C37-2102 Replacement Membrane Caps, pack of 3 C37-2100 complete kit
C37-2103 pH/mV/Temperature Probe, spare
C37-2104 Polymer Conductivity Cell, spare
DISSOLVED OXYGEN/°C EDGE® HYBRID MULTIPARAMETER METER, PRO-
FESSIONAL HAND HELD, WALL MOUNTING OR BENCH
Dissolved oxygen meter - specification is as per the Hybrid Multiparamer meter C30-
6225 but supplied with dissolved oxygen probe (C37-2152), refill electrolyte solution
(C37-2110) and 2 x dissolved oxygen membrane caps and rings (C37-2154).
Technical Data
Range: 0.00 to 45.00 ppm (mg/l); 0.0 to 300.0% saturation
Resolution: 0.01 ppm (mg/l); 0.1% saturation
Accuracy: ±1.5% of reading (± 1 digit)
Calibration: 1 or 2 point at 0% and 100% (in air)
Logging: up to 1000 (standard mode only - 400 for basic mode) records
organised in: manual log-on demand (max. 200logs), interval
logging (max 600 samples; 100 lots) C37-2170
C37-2170 Dissolved Oxygen Meter, Multi-parameter, Professional
140