ES                                                                        Spectrophotometers




         SCANNING DIODE RAY SPECTROPHOTOMETER
         Scanning spectrophotometers which use diode array technology to produce
         exceptionally fast results. Ideal for a variety of applications in education and routine
         testing in clinical, veterinary, pharmaceutical and QC laboratories.
         They offer measurement modes for single wavelength with basic absorbance and
         % transmittance; concentration calculated using a standard or a factor; optical
         density; quantitation with the ability to create a calibration curve using up to 6
         standards and 3 replicates; full spectrum scanning and kinetics where up to 3
         wavelengths can be measured simultaneously.
         The colour touchscreen user interface provides fast and easy set up and navigation
         of the instrument. The 4" display allows full spectrum scans, quantitation curves
         and kinetics runs to be viewed easily. The touchscreen capability enables users to
         zoom in and out and select spectral analysis points all by simply tapping the screen.
         The large sample chamber will easily accommodate the optional long path length
         cuvette holder and the heated 10x10mm cuvette holder which is ideal for
         thermostated measurements at 37°C. The sample chamber lid can also be left open
         during measurements which is ideal for samples in tall test tubes.
         There are two USB ports for data storage and printer connectivity. The easy access
         USB port on the front of the instrument can be used to easily store results and
         quantitation curves.
         Fitted with 10x10mm cuvette holder and supplied with instruction manual and
         universal power supply with UK, EU and US power leads.
         Technical Data
         Model                                         C61-6000                                      C61-6010
         Wavelength Range:              335 to 800nm                              198 to 800nm
         Wavelength Accuracy:                                           ± 2nm
         Wavelength Repeatability:                                    ± 2nm
         Spectral Bandwidth:                     7nm                                               5nm
         Absorbance Range:                                       - 0.300 to 2.500A
         Absorbance Accuracy:                         ± 0.01A at 1.0A and 546nm
         Absorbance Stability (A):                 ± 0.005A/h at 0.04A and 546nm
         Noise:                                                          ± 0.002A at 0.04A and
                                                                         ± 0.02A at 2.0A and 546nm
         Stray Light at 340nm, %T:               < 1%T according to ANSI/ASTM E387- 72
         Concentration Range:                                            ± 2500
         Concentration Calibration:              Blank with a single standard or factor
         Concentration Factor:                                            ± 1000
         Concentration Standard:                                       ± 1000
         Optical Density Factor:                                          ± 1000    C61-6000 & C61-6010
         Quantitation Range:                                               ± 2500
         Quantitation Calibration:                   Blank with up to 6 standards
         Curve Fit Algorithms:                        Linear and linear through zero
         Kinetics Measurement Time:                    15 to 9999 seconds
         Kinetics Number of wavelengths:                             3
         Kinetics Calibration:                                    Blank with a factor
         Kinetics Display:                                  Graphical and concentration
         Kinetics Analysis:                                              Concentration
         Spectrum Range:                  335 to 800nm                              198 to 800nm
         C61-6000  Spectrophotometer, Scanning Diode Ray, Visible, Range 335-800nm
         C61-6010  Spectrophotometer, Scanning Diode Ray, UV/Visible, Range 198-
         800nm
         Accessories & Spares for C61­6000 & C61­6010

         C61-6020 Heated Cell Accessory, 10 x 10mm cuvette holder, supplied with UK,
                           EU and US power leads
         C61-6030  Dust Cover
         C61-6040  Cuvette Holder, 10 x 10mm path length
         C61-6042  Test Tube Holder, accepts 10mm square cuvettes, 16mm and 24mm
                           diameter test tubes
         C61-6044  Cuvette Holder, 10 to 100mm path length
         C47-4125  Printer Accessory
         C30-6175  Paper Roll For Printer