ES                                                                         Conductivity Meters




         CONDUCTIVITY/TDS/SALINITY/°C EDGE® HYBRID METER, hand held, wall
         mounting or bench
         Features include a large 140mm LCD display with a capacitive touch keypad, auto-
         ranging or manual range selection, choice of EC, TDS and Salinity reading modes,
         automatic temperature compensation - NoTC (absolute), GLP data (records date,
         time, offset, and cell constant value (K)), adjustable EC to TDS conversion factor and
         adjustable temperature correction factor.
         Digital smart electrodes with 3.5mm phono connection enable it to automatically
         recognise and store sensor type, ID and calibration information. It is programmed
         for basic and advanced modes, has Log-on demand and interval logging, PC interface
         via micro-USB and data can be downloaded onto USB stick via standard USB.
         Supplied complete with digital platinum 4-ring conductivity/TDS probe (C30­5520),
         standards, USB cable 5V DC adapter, bench-top docking station with electrode
         holder, wall mount cradle, quality certificate and instruction manual.
         Technical Data
         Ranges:           Cond.: 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm;
                                  300 to 2999µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm;
                                  up to 500.0 mS/cm absolute EC
                                  TDS: 0.00 to 14.99mg/l (ppm); 15.0 to 149.9mg/l (ppm);
                                  150 to 1499mg/l (ppm); 1.50 to 14.99g/l; 15.0 to 100.0g/l;
                                  up to 400.0g/l absolute TDS using 0.80 conversion factor
         Temperature: -20.0 to 120.0 °C
         Salinity:          0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.0 to 80.0g/l
         Resolution:    Cond.: 0.01µS/cm; 0.1µS/cm; 1µS/cm; 0.01mS/cm; 0.1mS/cm
                                 TDS: 0.01mg/l (ppm); 0.1mg/l (ppm); 1 (ppm); 0.01g/l; 0.1g/l
                                 Temperature: 0.1°C
                                 Salinity:   0.1 % NaCl; 0.01 PSU; 0.01g/l
         Accuracy:       Cond. (@25°C): ±1% of reading (±0.5µS/cm or 1 digit, whichever is
         greater)
                                 TDS (@25°C): ±1% of reading (±0.03 ppm or 1 digit, whichever is
         greater)
                                 Temperature: ±0.1°C
                                 Salinity (@25°C): ±1% of reading                       C30-5500
         Calibration:    Cond.:  Single cell factor calibration; six standards available:
         84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm,
         one point offset: 0.00 µS/cm
                                 TDS: Through conductivity calibration
                                 Salinity:  PSU and g/l through conductivity calibration;
                                 % NaCl  one point with sea water standard (C30­5820)
         Temperature coefficient:  0.00 to 6.00%/°C (for EC and TDS only), default
         value is 1.90%/°C
         Auto standard recognition: 10µS, 84µS, 1413µS, 12.88mS
        C30-5500  Conductivity/TDS/Salinity/°C Edge® Hybrid Meter, hand held, wall
        mounting or bench

         Accessories &Spares
         Calibration solutions: C30­5040, C30­5050, C30­4620, C30­4640, C30­4810, C30­
         4820
         Spare Probe: C30­5520