Page 293 - Eagle Scientific Ltd - Catalogue
P. 293
ES Pipettors
PIPETTORS
PIPETTORS, FIXED VOLUME, FAB
Fixed volume, single channel, fully autoclavable pipettor. An extremely durable,
lightweight pipettor that is resistant to chemical and physical attack. It has a volume
lock to prevent accidental volume drifts and magnet assisted piston for unparalleled
consistency in results.
The slim, ergonomic design, unique shock-absorbing tip ejector and convenient
finger rest means the pipettor fits comfortably in your hand and reduces fatigue.
Features include a colour-coded operating knob to quickly differentiate between
pipette sizes. It is compatible with all common universal tips. Each pipettor is
individually tested and calibrated conforming to ISO 17025 and supplied with an
individual QC and calibration report in accordance with ISO 8655.
Volume, μl Inaccuracy, ±% Precission, ±%
C53-2009 2.5 2 1.6
C53-2014 5 1.3 1.2
C53-2021 10 1.2 0.6
C53-2026 20 1.0 0.3
C53-2036 25 1.0 0.3
C53-2041 50 0.7 0.3
C53-2046 100 0.6 0.2 C53-2009 et seq,
C53-2051 200 0.6 0.2
C53-2056 250 0.6 0.3
C53-2061 500 0.6 0.2
C53-2066 1000 0.6 0.2
C53-2076 2000 0.3 0.15
C53-2081 5000 0.3 0.15
C53-2086 10000 0.6 0.2
PIPETTORS, VARIABLE VOLUME, FAB
Variable volume, single channel, fully autoclavable pipettors. Extremely durable,
lightweight pipettors that are resistant to chemical and physical attack. They have C53-2009 et seq, in box
a volume lock to prevent accidental volume drifts and magnet assisted piston for
unparalleled consistency in results.
The slim, ergonomic design, unique shock-absorbing tip ejector and convenient
finger rest means the pipettors fit comfortably in your hand and reduces fatigue.
Features include a visible four-digit volume display and colour-coded operating knob
to quickly differentiate between pipette sizes. They are compatible with all common
universal tips. Each pipettor is individually tested and calibrated conforming to ISO
17025 and supplied with an individual QC and calibration report in accordance with
ISO 8655
Range Increments Tested at Inaccuracy Imprecission
μl μl μl ±% ±%
C53-2714 0.1 to 2.5 0.002 0.25/1.25/2.5 12/2.5/2.5 6/1.5/0.7
C53-2716 0.5 to 10 0.02 1/5/10 2.5/1.5/1 1.5/0.8/0.4
C53-2721 2 to 20 0.02 2/10/20 3/1.2/0.9 0.6/0.3/2
C53-2726 5 to 50 0.1 5/25/50 2/0.5/0.6 2/0.4/0.3
C53-2731 10 to 100 0.1 10/50/100 3/1/0.8 1/0.3/0.2
C53-2736 20 to 200 0.2 20/100/200 2.5/0.7/0.6 0.7/0.2/0.2
C53-2741 100 to 1000 1 100/500/1000 3/1/0.6 0.6/0.2/0.2
C53-2746 500 to 5000 10 500/250/5000 2.4/1.2/0.6 0.6/0.25/0.2
C53-2751 1000 to 10000 20 1000/5000/10000 3/0.8/0.6 0.6/0.2/0.15
C53-2756 Pipettors, variable volume, digital, Set/9 (1 of each of the C532714 to C53-2714 et seq,
C532751)
287